AMx36 • SSI & BiSS C-mode
4 - Electrical connections
WARNING
Power supply must be turned off before performing any electrical connection!
If wires of unused signals come in contact, irreparable damage could be caused
to the device. Thus they must be cut at different lengths and insulated
singularly.
Function
M12 8-pin
M8 type cable
0Vdc
1
Black
+Vdc
1
2
Red
Clock IN + / MA +
3
Yellow
Clock IN - / MA -
4
Blue
Data OUT + / SLO +
5
Green
Data OUT - / SLO -
6
Orange
Zero setting / Preset
7
White
Counting direction
8
Grey
Shield
Case
Shield
1
See the order code for power supply voltage level
EXAMPLE
AM36xx/xxxxBG
1
-...
+Vdc = +5Vdc ± 5%
AM36xx/xxxxBG
2
-...
+Vdc = +10Vdc +30Vdc
WARNING
When the power is switched on, above 3V supply vVdc must be applied
with a slew rate larger than 50V/s.
4.1 M12 8-pin connector
M12 8-pin connector
A coding
Male frontal side