AMx36 • SSI & BiSS C-mode
order to activate the preset, please consider that the system stores the new
resolution values, but zero sets the preset value. Thus you need to enter it again.
Load and save default parameters
: default parameters are set at the factory
by Lika Electronic engineers to allow the operator to run the device for standard
operation in a safe mode. As soon as the command is sent the default
parameters are uploaded and activated. All parameters which have been set
previously are overwritten, thus previously set values are lost. The complete list
of machine data and the relevant default parameters preset by Lika Electronic
engineers are available on page 35. Set “04” in the
register.
WARNING
Load and save default parameters
parameters which have been set previously are overwritten, thus previously set
values are lost!
As soon as the command is sent, the register is set back to "00" (
) automatically.
Wait min. 30 ms (EEPROM writing time) before using a new function.
Default = 00
Configuration
[49, rw]
register will be active immediately after
value permanently (set “01” in the register 48
).
Default = 20h = 00100000
2
Bit
Function
bit = 0
bit = 1
0
Not used
1
Not used
2
Enable
Disable
3
Not used
4
Not used
5
Gray
Binary
6
CW
CCW
7
Not used
Enable preset
It enables / disables the preset function. When you need to enter a new preset
value, you have first to enable the
registers. To do this set to 1 the bit 2
in this register, then enter the wished preset value next to the
registers and finally send the
Save parameters and activate Preset
MAN AMx36 SSI_BiSS E 1.1.odt
6 - BiSS C-mode interface
26 of 36