8. LW3 Programmers' Reference
Hybrid Modular Matrix Switcher series – User's Manual
92
Applied firmware package: v1.0.0 | LDC software: v2.4.0b3
8.15.14. Query the Health State of the HSMB
The query returns with the actual health status information about the High Speed Motherboard (HSMB).
Command and Response
ç
GETALL·/HEALTH/HSMB
æ
pr·/HEALTH/HSMB.Voltage0_1V0=
<voltage0>
æ
pr·/HEALTH/HSMB.Voltage1_1V2=
<voltage1>
æ
pr·/HEALTH/HSMB.Voltage2_1V5=
<voltage2>
æ
pr·/HEALTH/HSMB.Voltage3_3V3=
<voltage3>
æ
pr·/HEALTH/HSMB.Voltage4_5V0=
<voltage4>
æ
pr·/HEALTH/HSMB.Voltage5_12V0=
<voltage5>
æ
pr·/HEALTH/HSMB.Voltage6_48V0=
<voltage6>
æ
pr·/HEALTH/HSMB.Temperature0=
<temperature0>
æ
pr·/HEALTH/HSMB.Temperature1=
<temperature1>
æ
pr·/HEALTH/HSMB.Temperature2=
<temperature2>
æ
pr·/HEALTH/HSMB.FanSpeed0=
<fanspeed0>
æ
pr·/HEALTH/HSMB.FanSpeed1=
<fanspeed1>
æ
pr·/HEALTH/HSMB.FanSpeed2=
<fanspeed2>
æ
pr·/HEALTH/HSMB.UnevenCurrentShare=
<logical_value>
æ
pr·/HEALTH/HSMB.BoardsInRightSlotState=
<status>
æ
pr·/HEALTH/HSMB.TemperatureState=
<status>
æ
pr·/HEALTH/HSMB.VoltageState=
<status>
æ
pr·/HEALTH/HSMB.FanState=
<status>
æ
pr·/HEALTH/HSMB.OverallHealthState=
<status>
Example
ç
GETALL /HEALTH/HSMB
æ
pr /HEALTH/HSMB.Voltage0_1V0=1.04 V;1.02;1.08;1.00;1.10;1.03;1.04
æ
pr /HEALTH/HSMB.Voltage1_1V2=1.17 V;1.16;1.24;1.14;1.26;1.17;1.17
æ
pr /HEALTH/HSMB.Voltage2_1V5=1.48 V;1.46;1.55;1.43;1.58;1.48;1.48
æ
pr /HEALTH/HSMB.Voltage3_3V3=3.32 V;3.20;3.40;3.14;3.47;3.32;3.32
æ
pr /HEALTH/HSMB.Voltage4_5V0=5.06 V;4.95;5.25;4.85;5.36;5.06;5.12
æ
pr /HEALTH/HSMB.Voltage5_12V0=0.26 V;11.50;12.60;11.00;13.00;0.26;0.26
æ
pr /HEALTH/HSMB.Voltage6_48V0=0.00 V;46.00;52.00;44.00;56.00;0.00;0.00
æ
pr /HEALTH/HSMB.Temperature0=65.00 C;0.00;75.00;0.00;85.00;0.00;72.50
æ
pr /HEALTH/HSMB.Temperature1=72.50 C;0.00;75.00;0.00;85.00;65.00;72.50
æ
pr /HEALTH/HSMB.Temperature2=72.50 C;0.00;75.00;0.00;85.00;65.00;72.50
æ
pr /HEALTH/HSMB.FanSpeed0=0.00 RPM;10.00;65535.00;0.00;65535.00;0.00;0.00
æ
pr /HEALTH/HSMB.FanSpeed1=0.00 RPM;10.00;65535.00;0.00;65535.00;0.00;0.00
æ
pr /HEALTH/HSMB.FanSpeed2=0.00 RPM;10.00;65535.00;0.00;65535.00;0.00;0.00
æ
pr /HEALTH/HSMB.UnevenCurrentShare=false
æ
pr /HEALTH/HSMB.BoardsInRightSlotState=OK
æ
pr /HEALTH/HSMB.TemperatureState=OK
æ
pr /HEALTH/HSMB.VoltageState=OK
æ
pr /HEALTH/HSMB.FanState=OK
æ
pr /HEALTH/HSMB.OverallHealthState=OK
8.15.15. Query the Health State of the CECU
The query returns with the actual health status information about the Central Electronic Control Unit (CECU).
Command and Response
ç
GETALL·/HEALTH/CECU
æ
pr·/HEALTH/CECU.Temperature0=
<temperature>
æ
pr·/HEALTH/CECU.TemperatureState=
<status>
æ
pr·/HEALTH/CECU.OverallHealthState=
<status>
Example
ç
GETALL /HEALTH/CECU
æ
pr /HEALTH/CECU.Temperature0=47.72 C;0.00;65.00;0.00;70.00;44.24;53.52
æ
pr /HEALTH/CECU.TemperatureState=OK
æ
pr /HEALTH/CECU.OverallHealthState=OK