8. LW3 Programmers' Reference
Hybrid Modular Matrix Switcher series – User's Manual
70
Applied firmware package: v1.0.0 | LDC software: v2.4.0b3
8.4.13.
Restore the Factory Default Settings
Command and Response
#factory
ç
CALL·/SYS:factoryDefaults()
æ
mO·/SYS:factoryDefaults=
Example
ç
CALL /SYS:factoryDefaults()
æ
mO /SYS:factoryDefaults=
The device is restarted, current connections are terminated, and the default settings are restored. See the
section.
8.5. I/O Board Management
8.5.1. Query the Status of a Board
The query returns the actual status of the selected I/O board in the matrix frame.
Command and Response
ç
GET·/SYS/
<board>
.Status
æ
pr·/SYS/
<board>
.Status=
<status>
Parameters
Identifier
Parameter
description
Value
Value description
<board>
The identifier of
the board.
IB1...IB6
Input board ID, the values can be IB1, IB2,
IB3, IB4, IB5 or IB6.
OB1...OB6
Output board ID, the values can be OB1,
OB2, OB3, OB4, OB5 or OB6.
LS1...LS4
Auxiliary (LS - Low Speed) board ID, the
values can be LS1, LS2, LS3, or LS4.
<status>
Current status of
the I/O board
No power
Board is present but not powered.
Not present
Board is not present.
Seated
Board is seated into the slot.
Connecting
Connecting to the CPU.
Connected
Connected to the CPU but not initialized
yet.
Initializing
Under initialization.
Operational
Board is operational and ready to use.
Reset
Board is rebooting.
Debug
Board is in debug mode.
FirmwareUpgradeEthernet
The firmware of the board is being
upgraded by the matrix frame.
BootloadMode
Board is in bootlode (firmware upgrade)
mode which might be happened after
an unsuccesful fimrware upgrade
procedure. Restarting the firmware
upgrade procedure is recommended.
InWrongSlot
The board is seated to wrong slot. See the
layout of the I/O board slot in the
section.
Unknown
The status of board is unknown. Reseating
of the board is recommended.