8. LW3 Programmers' Reference
Hybrid Modular Matrix Switcher series – User's Manual
71
Applied firmware package: v1.0.0 | LDC software: v2.4.0b3
Example
ç
GET /SYS/OB1.Status
æ
pr /SYS/OB1.Status=Operational
8.5.2. Query the Number of Seated I/O Boards
The query returns the number of the seated I/O boards in the matrix frame, including IB, OB, and AUX (Low
Speed) boards.
Command and Response
ç
GET·/SYS/UPDATE.NumberOfBoards
æ
pr·/SYS/UPDATE.NumberOfBoards=
<number>
Example
ç
GET /SYS/UPDATE.NumberOfBoards
æ
pr /SYS/UPDATE.NumberOfBoards=7
8.5.3. Query the List of Seated I/O Boards
The query returns the list of the seated I/O boards in the matrix frame, including IB, OB, and AUX (Low Speed)
boards.
Command and Response
ç
GET·/SYS/UPDATE.BoardsInSeatedState
æ
pr·/SYS/UPDATE.BoardsInSeatedState=
<board_slot1>
;
<board_slot2>
;
...<board_slotX>
Example
ç
GET /SYS/UPDATE.BoardsInSeatedState
æ
pr /SYS/UPDATE.BoardsInSeatedState=LS1;LS2;IB2;IB4;OB1;OB2;OB3;OB4;OB5
8.5.4. Query the List of Operational I/O Boards
The query returns the list of the operational I/O boards in the matrix frame, including IB, OB, and AUX (Low
Speed) boards.
Command and Response
ç
GET·/SYS/UPDATE.BoardsInOperationalState
æ
pr·/SYS/UPDATE.BoardsInOperationalState=
<board_slot1>
;
<board_slot2>
;
...<board_slotX>
Example
ç
GET /SYS/UPDATE.BoardsInOperationalState
æ
pr /SYS/UPDATE.BoardsInOperationalState=LS1;LS2;IB2;IB4;OB1;OB2;OB3;OB4;OB5
8.5.5. Query the List of Failed I/O Boards
The query returns the list of the failed I/O boards in the matrix frame, including IB, OB, and AUX (Low Speed)
boards.
Command and Response
ç
GET·/SYS/UPDATE.BoardsInErrorState
æ
pr·/SYS/UPDATE.BoardsInErrorState=
<board_slot1>
;
<board_slot2>
;
...<board_slotX>
Example
ç
GET /SYS/UPDATE.BoardsInErrorState
æ
pr /SYS/UPDATE.BoardsInErrorState=LS1;LS2;IB2;IB4;OB1;OB2;OB3;OB4;OB5
8.5.6. Query the Product Name of the I/O Board
The name of the product is a read-only parameter and cannot be modified.
Command and Response
#producttype
ç
GET·/SYS/
<board>
.ProductName
æ
pr·/SYS/
<board>
.ProductName=
<Product_name>
Example
ç
GET /SYS/IB1.ProductName
æ
pr /SYS/IB1.ProductName=MX2M-4HDMI20-IB
8.5.7. Query the Serial Number of the I/O Board
Command and Response
#serialnumber
ç
GET·/SYS/
<board>
.SerialNumber
æ
pr·/SYS/
<board>
.SerialNumber=
<serial_number>
Example
ç
GET /SYS/LS1.SerialNumber
æ
pr /SYS/LS1.SerialNumber=87654321