inDOMO HP

 - Platform lift

FINAL TESTS

IM.TEC.028.EN_rev.10.2

   -  November 2015

All rights reserved

List of installed components:

Safety components 

Component type 

Landing door lock
Block valve 
Safety brake 
Electronic safety device  

(floor levelling)

LIFT N° ____________________________________________

YEAR OF MANUFACTURE: ______________________________

LOAD:  __________________________________________ kg

TRAVEL:   _________________________________________  m

N° STOPS: ________________________

N° SERVICES: ______________________ N° CAR ACCESSES: __________________

Manufacturer: LIFTINGITALIA S.r.l.
Address: V. Caduti del Lavoro, 16 - 43058
Bogolese di Sorbolo (PR) - ITALY
ph. +39 0521.695311 - fax. +39 0521.695313

Supplier: LIFTINGITALIA S.r.l.
Address: V. Caduti del Lavoro, 16 - 43058
Bogolese di Sorbolo (PR) - ITALY
ph. +39 0521.695311 - fax. +39 0521.695313

Owner: ____________________________________________
Address: ___________________________________________

___________________________________________

Ph. ______________________ -  Fax. ____________________

Installation site: _____________________________________
Address: ___________________________________________

___________________________________________

Ph. ______________________ -  Fax. ____________________

Installer: ___________________________________________
Address: ___________________________________________

___________________________________________

Ph. _________________ -  Fax. ________________

Tests effected (date) : __________________________________
by  ________________________________________________
as installer’s representative 

Special notes  : ____________________________________________________________________________________________

____________________________________________________________________________________________
____________________________________________________________________________________________

Summary of Contents for InDomo HP

Page 1: ...a Caduti del Lavoro 16 43058 Bogolese Sorbolo PR Italy Phone 39 0521 695311 Fax 39 0521 695313 www verticogroup it info liftingitalia it 1 13 IM TEC 028 EN_rev 10 2 November 2015 inDOMOHP Platform lif...

Page 2: ...5 2 4 ORIGINAL MATERIALS FROM LIFTINGITALIA 5 2 5 STRUCTURAL TEST 5 2 6 MAXIMUM STATIC PRESSURE 5 2 7 HYDRAULIC CIRCUIT 5 2 8 BLOCK VALVE 5 2 9 OVERLOAD MANOSTAT 6 2 10 ASCENT AND DESCENT SPEED 6 2 11...

Page 3: ...due to sharp angles or protruding parts Risk of damage to mechanical parts e g during incorrect installation Fire hazard Hanging load Risk of skin injury Risk of falling No entry Materials to be prot...

Page 4: ...y each of them contains the requirements to be matched and the way to check them The operations described in this paragraph can be carried out by adequately qualified personnel The below listed operat...

Page 5: ...mities of the lift MAXIMUM LOAD 2 6 MAXIMUM STATIC PRESSURE Check the maximum static pressure with the maximum load i bring the car to the upper stop and open the valve of the pressure gauge ii Pay at...

Page 6: ...ecision either fully loaded or empty car i use the landing operation panel for commands ii with a loaded car command an upwards travel letting the lift stop by itself iii open the landing door and wit...

Page 7: ...ess and hold any operation button the car will descend to the lowest floor so the door can be open vi refresh 2 15 SHAFT CLOSURE The shaft must be closed completely 2 16 COMMANDS Check the correct exe...

Page 8: ...he shaft wall in front of the entrance ii CAR WITHOUT DOORS the distance between the shaft and the entrances must be max 20 mm valid for the full travel height ii CAR WITH DOORS the horizontal distanc...

Page 9: ...ximum 1 4 maximum static pressure described in the paragraph 2 4 of this manual v refresh 2 26 PULLEY SAFETY COVERS Check the presence and the correct assembly of the safety covers applied on the pull...

Page 10: ...ons and humidity and can keep the constant temperature comprised between 5 and 40 C ii the area in front of the cabinet door is clean and its width and height are suffucient for a safe access iii a re...

Page 11: ...ner ____________________________________________ Address ___________________________________________ ___________________________________________ Ph ______________________ Fax ____________________ Inst...

Page 12: ...____________________________________ __________________________________________________________________ __________________________________________________________________ Date _______________ Installe...

Page 13: ..._______________________________________________ __________________________________________________________________ __________________________________________________________________ Date _____________...

Reviews: