background image

10

  

(13)

inDOMO HP

 - Platform lift

FINAL TESTS

IM.TEC.028.EN_rev.10.2

   -  November 2015

All rights reserved

2.31   PHOTOCELLS OR LIGHT BARRIERS (if any)

To check these devices proceed as follows:

CAR WITHOUT DOORS 

With the car moving, catch the ray of a photocell (light barrier); 

the lift will stop and remain stationary until the removal 

of the obstacle

. Then send the car upwards.

CAR WITH DOORS 

when the car is stationary at a stop while the doors are closing, catch the ray of a photocell (light barrier), 

the car doors 

will open and remail open until the removal of the obstacle

.

2.32   BUTTON ENABLING KEY (optional)

To test the key proceed as follows:

i.  

in the car, without commuting to the enabling key, try to send the car upwards and downwards: the lift will not 

respond;

ii.   press the alarm button to activate the siren;
iii.   commute to the key and repeat the same operations: the lift will start moving regularly;
iv.   commute to the landing key and repeat from each floor.

2.33   CONTROL CABINET

Check the following conditions:

i.  

the control cabinet is located in a suitable room, protected from bad weather conditions and humidity, and can  keep 

the constant temperature comprised between 5 and 40 °C;

ii.   the area in front of the cabinet door is clean, and its width and height are suffucient for a safe access;
iii.   a relevant lighting is available, to ensure a perfect visibility and component identification inside the cabinet;
iv.   the hoses and electrical wires connected to the  cabinet are adequately protected from damages, and inspectable.

2.34   SIGNAGE
Check the correct application of the following plates and signs

:

i.  

in the pit (access might be dangerous without safety devices);

ii.   on the car roof (not bearing surface);
iii.   on the control cabinet (electrical hazard, emergency operation instructions);
iv.   beside the main supply switch (operation mode);
v.   beside the red emergency descent button (for an easy identification);
vi.   in the car (duty load, capacity, name of manufacturer, emergency instructions for the COP in case of power cuts);
vii.   close to the outer alarm system of the lift (to explain its function) .

2.35   NOISE EMISSION
Verify that the sound pressure emission does not exceeds the maximum level in the following areas (± 3 dB(A))

:

i.  

inside of the car: 60 dB(A);

ii.   by the landing area, at a distance of 1 metre from the landing door: 55 dB(A);
iii.   in front of the machine room cabinet , at a distance of 1 metre: 55 dB(A);

Summary of Contents for InDomo HP

Page 1: ...a Caduti del Lavoro 16 43058 Bogolese Sorbolo PR Italy Phone 39 0521 695311 Fax 39 0521 695313 www verticogroup it info liftingitalia it 1 13 IM TEC 028 EN_rev 10 2 November 2015 inDOMOHP Platform lif...

Page 2: ...5 2 4 ORIGINAL MATERIALS FROM LIFTINGITALIA 5 2 5 STRUCTURAL TEST 5 2 6 MAXIMUM STATIC PRESSURE 5 2 7 HYDRAULIC CIRCUIT 5 2 8 BLOCK VALVE 5 2 9 OVERLOAD MANOSTAT 6 2 10 ASCENT AND DESCENT SPEED 6 2 11...

Page 3: ...due to sharp angles or protruding parts Risk of damage to mechanical parts e g during incorrect installation Fire hazard Hanging load Risk of skin injury Risk of falling No entry Materials to be prot...

Page 4: ...y each of them contains the requirements to be matched and the way to check them The operations described in this paragraph can be carried out by adequately qualified personnel The below listed operat...

Page 5: ...mities of the lift MAXIMUM LOAD 2 6 MAXIMUM STATIC PRESSURE Check the maximum static pressure with the maximum load i bring the car to the upper stop and open the valve of the pressure gauge ii Pay at...

Page 6: ...ecision either fully loaded or empty car i use the landing operation panel for commands ii with a loaded car command an upwards travel letting the lift stop by itself iii open the landing door and wit...

Page 7: ...ess and hold any operation button the car will descend to the lowest floor so the door can be open vi refresh 2 15 SHAFT CLOSURE The shaft must be closed completely 2 16 COMMANDS Check the correct exe...

Page 8: ...he shaft wall in front of the entrance ii CAR WITHOUT DOORS the distance between the shaft and the entrances must be max 20 mm valid for the full travel height ii CAR WITH DOORS the horizontal distanc...

Page 9: ...ximum 1 4 maximum static pressure described in the paragraph 2 4 of this manual v refresh 2 26 PULLEY SAFETY COVERS Check the presence and the correct assembly of the safety covers applied on the pull...

Page 10: ...ons and humidity and can keep the constant temperature comprised between 5 and 40 C ii the area in front of the cabinet door is clean and its width and height are suffucient for a safe access iii a re...