Static Anchor Procedure
CAUTION: If it is possible that the length of your bolt will not provide the minimum requirement of 2.5”
(63.5mm) of engagement, a longer anchor should be used.
1.
Place unit into position to be mounted and cycle unit to set stance.
2.
Each foot
must
get at least one static fastener.
3.
Wearing protective glasses, drill down into the flooring to the required depth as perpendicular as possible,
ensuring that the foot thickness is being accounted for; refer to
Anchor Selection
and
Foot Dimensions
.
4.
Insert fastener and tighten to 18 Foot-Pounds (24Nm) for 1/4” (6mm) anchor or 40 Foot-Pounds (54Nm) for 3/8”
(8mm) anchor.
NOTE: If the legs/frame do not contact the mounting surface
DO NOT
pull down with the fastener or anchor.
Loosen frame hardware and re-tighten to allow machine to align.
Page 49 of 51