CASE 4: Connecting 2
nd
Circuit
Floor heating loop
Mix
2
nd
circuit temp. sensor
Mix Kit
[Room B] Additional zone (High Temp.)
[Room A] Main Zone zone (Low Temp.)
Floor heating loop
Radiator
Radiator
M / F
Buffer
Tank
R
T
Outdoor
Indoor
High Temperature
Room Thermostat
(Field supply)
2way valve (Field supply)
By-pass valve(Field supply)
Low Temperature
Shut-off valve
Magnetic Filter (Mandatory)
Air vent (Field supply)
M / F
Pressure Regulation valve
(Field supply)
3way valve
(Field supply)
Pump(Field supply)
Mix Kit (Field supply)
NOTE
• Mix Kit
- You can install it when you want to set the temperature of two rooms individually
- When heating, Main Zone can not be higher than Add Zone.
- When cooling, Main Zone can not be lower than Add Zone.
- The types and specifications of the Mix Kit are to comply with Chapters 4 and 7 of the
Installation Manual.