79
ACCESSORIES INSTALLATION
ENGLISH
Energy State
This product provides energy states that enable customers to use as much as possible of their
own renewable energy. It can shift setpoints depending on input signal from Energy Storage
System (ESS) or from any other third-party device using Modbus RTU or Digital 230V inputs.
Available Energy States
There are 8 energy states available. 4 fixed and 4 customizable - each with the possibility to
enhance selfconsumption of renewable energy.
Energy
state
Command
Battery
State of
charge
Operation (standard setting)
Heating
Cooling
Domestic Hot Water
Setting
Range
Setting
Range
Setting
Range
1
Operation Off
(Utility lock)
Low
Forced
internal
operation off
Fixed
Forced internal
operation off
Fixed
Forced internal
operation off
Fixed
2
Normal
Operation
Normal
Maintain
operation
status status
Fixed
Maintain
operation status
Fixed
Maintain
operation status
Fixed
3
Operation On
Recommend
High
Increase 2 °C
from target
temperature
Fixed
Maintain
operation Status
Fixed
Increase 5 °C
from target
temperature
Fixed
4
Operation On
Recommend
Very High
Maintain
operation
status
Fixed
Maintain
operation status
Fixed
DHW Target
80 °C
Fixed
5
Operation On
Commend
Very High
Increase from
target
temperature
0/+30
(Default : +5)
Decrease from
target
temperature
0/-30
(Default : -5)
Increase from
target
temperature
0/+50
(Default : +30)
6
Operation On
Recommend
High
Increase from
target
temperature
0/+30
(Default : +2)
Decrease from
target
temperature
0/-30
(Default : -2)
Increase from
target
temperature
0/+50
(Default : +10)
7
Operation
Save
Low
Decrease from
target
temperature
0/-30
(Default : -2)
Increase from
target
temperature
0/+30
(Default : +2)
Decrease from
Target
Temperature
0/-50
(Default : 0)
8
Operation
Super Save
Very
Low
Decrease from
target
temperature
0/-30
(Default : -5)
Increase from
target
temperature
0/+30
(Default : +5)
Decrease from
Target
Temperature
0/-50
(Default : 0)
Summary of Contents for Therma V HM091MRS