64
ACCESSORIES INSTALLATION
ENGLISH
• When you remove the remote controller from the installation plate, insert a small flat head
screwdriver into the bottom side separation hole and turn clockwise to separate the remote
controller.
- There are 2 separation holes at the bottom part. Slowly separate one by one.
- Be careful not to damage the internal parts during the removal.
<Order of Separation>
• Use the connection cables to connect the indoor unit with the remote controller.
• For the following cases, separately purchase and use the cables suitable for the situation.
- Do not install the cable over 50 m. (It may cause communication issues.)
- If the distance between the wired remote controller and the unit is 10 m or more : 10 m
extension cable (model name: PZCWRC1)
During the wired remote controller installation, do not bury it in the wall. (It may cause
temperature sensor failure.)
Do not install the cable over 50 m. (It may cause communication defect.)
When you install the extension cable, carefully check the direction of the connectors on the
remote controller side and the product side before the installation.
Specification of extension cable: AWG 24, 3 conductor or above.
Please check if connector is normally connected.
Connecting cable
Unit side
OK
DC 12 V
Red
Signal
Yellow
GND
Black
W
a
ll Side
Indoor PCB
CN_REMO
NOTE
Summary of Contents for Therma V HM091MRS