39
INSTALLATION
ENGLISH
Circuit Breaker Specification
Perform the electrical wiring work according to the electrical wiring connection.
• All wiring must comply with local requirements.
• Select a power source that is capable of supplying the current required by the appliance.
• Use a recognized ELCB(Electric Leakage Circuit Breaker) between the power source and the
unit. A disconnection device to adequately disconnect all supply lines must be fitted.
• Model of circuit breaker recommended by authorized personnel Only.
• Select a circuit breaker suitable for the current specification.
1) Maximum running current is the maximum current value maintained during the operation of
the unit.
2) Current(Max.) is the maximum current value when a compressor of unit is off.
Unit
Backup
Heater
Live Signal
for Backup Heater
(A+B)
Live Signal
for DHW Tank kit
CB
CB
DHW
Tank kit
Switch
Box
Power source
Sensor
Signal
ELCB
CB
DHW
Tank
*CB : Circuit Breaker
*ELCB : Electric Leakage Circuit Breaker
Model name
Maximum Running
Current[A]
1)
Current (Max.)
[A]
2)
Chassis
Phase[Ø]
Capacity [kW]
UN36A
1
5
14.2
27.6
7
15.7
9
23.0
UN60A
1
9
15.0
15.0
12
33.0
42.0
14
34.0
16
35.0
3
12
12.0
18.0
14
12.5
16
13.0