CONFIGURATION
ENGLISH
Outdoor PCB General Information
OFF is selected
ON is selected
OFF
ON
SW2
1 2 3 4 5 6 7 8 9
10
Description
Setting
Default
Peak Control
Low Noise Mode
3
3
Max Mode
2
Limited Low Noise Mode
2
Normal Low Noise Mode
Peak Control : To limit maximum
current (Power saving)
3
2
DIP Switch Information
* Input current value can be limited by DIP Switch operation.
h
Only DIP Switch no. 2 and no.3 has a function. Others have no function.
h
When setting the limited low noise mode, Mode can be exited to secure capacity after
operating for a certain time.
NOTE
Model Name
Max. Mode Running
Current (A)
Peak Control Mode
Running Current (A)
Chassis
Phase (Ø) Capacity (kW)
Mode
UN36A
1
5, 7, 9
Cooling
23
17
Heating
23
17
UN60A
1
9
Cooling
15
14
Heating
15
14
12, 14, 16
Cooling
35
25
Heating
35
27
3
12, 14, 16
Cooling
15
10
Heating
15
12