7. Function list
7-21
SV-iC5
I/O group
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
2 -
3
-
3 -
3
3
4
3
- -
5
3
-
3
6
3
3
-
7
3
3
3
I60 [Inverter
station
number]
1/32
This parameter is set when the inverter
uses RS485 communication.
1 O
Select the Baud rate of the RS485
0 1200
bps
1 2400
bps
2 4800
bps
3 9600
bps
I61 [Baud
rate]
0/4
4 19200
bps
3 O
It is used when frequency command is
given via V1 and I terminal or communication
option.
0 Continuous
operation
1
Free Run stop (Coast to stop)
I62 [Drive
mode
select after
loss of
frequency
command]
0/2
2
Decel to stop
0 O
I63 [Wait
time
after loss of
frequency
command]
0.1/12
[sec]
This is the time inverter determines
whether there is the input frequency command
or not. If there is no frequency command input
during this time, inverter starts operation via
the mode selected at I62.
1.0
-
12-7