11. Monitoring
11-2
SV-iC5
User display select
Group
LED Display
Parameter Name
Set
value
Min/Max
range
Factory
default
Unit
Drive group
vOL
[User display select]
-
Function
group 2
H73
[Monitoring item select]
-
0/2
0
The selected item in H73- [Monitoring item select] can be monitored in vOL- [User display select].
H73 : Select one of the desired item numbers.
0 Output
voltage
[V]
1
Output power [kW]
H73 [Monitoring
item
select]
2 Torque
Enter motor efficiency indicated on motor nameplate to H36 to display correct torque
Power on display
Group
LED
display
Parameter Name
Setting
Factory
default
H72
[Power on display]
0
Frequency command (0.0)
1
Accel time (ACC)
2
Decel time (DEC)
3
Drive mode (drv)
4
Frequency mode (Frq)
5
Multi-step frequency 1
6
Multi-step frequency 2
7
Multi-step frequency 3
8
Output current (CUr)
9
Motor rpm (rPM)
10
Inverter DC link voltage (dCL)
11
User display select (vOL)
12
Fault display 1
Function
group 2
`
13
Fault display 2
0
Select the parameter to be displayed on the keypad when the input power is first applied.
Summary of Contents for SV-iC5 Series
Page 8: ...Table of Contents viii SV iC5 ...
Page 22: ...3 Wiring 3 6 SV iC5 Notes ...
Page 38: ...5 Programming keypad 5 14 SV iC5 Notes ...
Page 42: ...6 Basic operation 6 4 SV iC5 Notes ...
Page 64: ......
Page 68: ......
Page 108: ...10 Advanced functions 10 20 SV iC5 Notes ...
Page 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes ...
Page 136: ......