Installation
13
3
Ins
talla
tion
Connecting Display device
The video signal connection between the camera and the
monitor.
Display device connection
ALARM input connection
You can connect up to 4 alarm sensors to the camera. Each
alarm sensor should be connected with Alarm IN COM. You
can adjust the signal state to NO (normally open) or NC
(normally closed) through the setup menu.
1. Connect the RJ-45 Adapter cable to the PORT A (RJ-45)
cable of the camera.
2. Connect the alarm device to the RJ-45 Adapter cable.
When connecting lines, check and connect the color
lines of the each device correctly. Refer to the below
tables for color line information.
CAUTION
Do not connect one alarm sensor to the several camera’s
alarm input connector.
Alarm input connection
E
D
C
B
A
G
F
H
PORT A
RJ-45 Adapter cable
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
RJ-45 Adapter cable
Port A
RJ-45 Adapter cable
No
Description
Color
A
RS-485 +
White
B
RS-485 -
Orange
C
NC
Black
D
ALARM IN COM
Red
E
ALARM IN 1
Green
F
ALARM IN 2
Yellow
G
ALARM IN 3
Blue
H
ALARM IN 4
Brown