48
Test 1
120V AC Electrical Supply
WARNING
•
When measuring power, be sure to wear insulated gloves to avoid an electric shock.
•
Failure to follow these instructions can result in death or electric shock.
Trouble Symptom
Measurement Condition
No power was applied to controller. (LED, LCD Display off)
With Dryer Power On; connector linked to controller.
NO
NO
YES
YES
YES
NO
Check the outlet, is the voltage
110V ~ 125V AC?
¥ Check the fuse or
circuit breaker.
¥ Check if power
cord is properly
connected.
¥ Reconnect the
controller.
Check if the voltage measured between
Connector BK2 or WH2- (Black Wire)
Linked to the Controller and YL3-
(White Wire) Is 110~125V?
Check if the controller wire is
disconnected.
Check if terminal block and power cord
are connected (Check Plug).
- Does Power Cord N (Natural) line match
to Terminal Center N (Natural) line?
Replace controIler.
BK2 or WH2 YL3
1
2
1
2
Summary of Contents for GDL1329CED3
Page 13: ...13 4 INITIAL STEPS FOR INSTALLING YOUR DRYER ...
Page 14: ...14 ...
Page 15: ...15 ...
Page 16: ...16 ...
Page 17: ...17 ...
Page 28: ...28 ...
Page 29: ...29 6 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS ...
Page 36: ...36 9 EXHAUST REQUIREMENTS AND MAINTENANCE ...
Page 40: ...40 10 DRYER CYCLE PROCESS ...
Page 42: ...42 44 ...
Page 43: ...43 ...
Page 44: ...44 12 MOTOR DIAGRAM AND SCHEMATIC Centrifugal switch Centrifugal switch Pull Drive forward ...
Page 45: ...45 13 CONTROL LAY OUT PWB ASSEMBLY DISPLAY LAY OUT PWB ASSEMBLY LAY OUT ...
Page 50: ...50 ...
Page 51: ...51 Trouble Symptom Measurement Condition Air TEMP RES k Air TEMP RES k Air TEMP RES k ...
Page 55: ...55 Trouble Symptom Measurement Condition ...
Page 56: ...56 Trouble Symptom Measurement Condition ...
Page 57: ...57 16 ERROR MODE ...
Page 61: ...61 18 CHANGE GAS SETTING NATURAL GAS PROPANE GAS ...
Page 62: ...62 ...
Page 71: ...71 EXPLODED VIEW 20 20 1 1 Control Panel Plate Assembly Coin OPL Type A210 A120 A116 A110 ...
Page 72: ...72 20 1 2 Control Panel Plate Assembly Card Type A210 A120 A117 A116 A110 ...