- 30 -
Refrigeration Cycle Diagram
1. FM-4480N6L (Cooling & Heating modes)
A
B
C
D
E
F
Heat Exchanger
Indoor Unit
Outdoor Unit
3-WAY
Valve
Heat Exchanger
4-WAY
Valve
Comp
ex)
LEV
Cooling & Deice
Heating
INDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
B(Length)
D(Length)
A(Height)
C(Height)
9.52mm(3/8")
6.35mm(1/4")
12.7mm(1/2")
6.35mm(1/4")
7.5
7.5
25
25
15.88mm(5/8")
6.35mm(1/4")
Pipe Size
GAS
LIQUID
Max. length
(m)
Additional
Refrigerant (g/m)
Max. Elevation
(m)
Standard Length
(m)
** A, B mean indoor unit higher located than outdoor unit.
C, D mean outdoor unit higher located than indoor unit.
For installation over rated distance, 25g of refrigerant should be added for each meter in Heat pump Model.
ex) When installed at a distance of 15m, 75g of refrigerant should be added in Heat pump Model.
(15 – 7.5) x 25g = 187.5g
(Rated performance for refrigerant line length of : 7.5m)
Summary of Contents for FMN0760NL
Page 94: ... 94 FMN1260NT FMN1860NT ...
Page 95: ... 95 FMN1260NFM B D TOP VIEW BOTTOM VIEW ...
Page 96: ... 96 FMN1860NV ...
Page 97: ... 97 2 Outdoor Unit MAIN P C B ASM FMU4480N6L ...
Page 98: ... 98 PCB PWB ASSY SUB ...
Page 99: ... 99 3 Display ASSY FMN1860NV FMN1260NFM B D TOP VIEW BOTTOM VIEW ...
Page 100: ... 100 4 SUB P W B ASSEMBLY FMN1260NFM B D TOP VIEW BOTTOM VIEW ...
Page 101: ... 101 Schematic Diagram 1 Indoor Unit FMN0760NL FMN0960NL FMN1260NL FMN1860NL ...
Page 103: ... 103 FMN1260NFM B D ...
Page 104: ... 104 FMN1860NV RY 4WAY RY OUTFAN ...
Page 122: ...P No 3828A20208A August 2002 Printed in Korea ...