- 31 -
Installation of Indoor, Outdoor Unit
Front
Right
Rear right
Rear left
Down right
Left
More than 5 cm
More than eye-level
More than
5 cm
More than
5 cm
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
30 or more
Abo
ve
250
330 or less
100
or more
50 or
more
50 or
more
30 or less
Floor
1. Selection of the best location
(1) Indoor unit
1. Room Type Indoor Unit
•
There should not be any heat source or steam near the
unit.
• There should not be any obstacles to prevent the air cir-
culation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into considera-
tion.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.
2. Cassette Type Indoor Unit
• There should not be any heat source or steam near the
unit.
• There should not be any obstacles to the air circulation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceil-
ing, or other obstacles.
• The indoor unit must have the maintenance space around
3. Art Cool Type Indoor Unit
• Do not have any heat or steam near the unit.
• Select a place where there are no obstacles in front of
the unit.
• Make sure that condensation drainage can be conve-
niently routed away.
Do not install near a doorway.
• Ensure that the space around the left and right of the
unit is more than 50cm. The unit should be installed as
high on the wall as possible, allowing a minimum of
10cm from ceiling.
• Use a stud finder to locate studs to prevent unneces-
sary damage to the wall.
More than 10cm
More than 50cm
More than 2m
More than 50cm
Summary of Contents for FMN0760NL
Page 94: ... 94 FMN1260NT FMN1860NT ...
Page 95: ... 95 FMN1260NFM B D TOP VIEW BOTTOM VIEW ...
Page 96: ... 96 FMN1860NV ...
Page 97: ... 97 2 Outdoor Unit MAIN P C B ASM FMU4480N6L ...
Page 98: ... 98 PCB PWB ASSY SUB ...
Page 99: ... 99 3 Display ASSY FMN1860NV FMN1260NFM B D TOP VIEW BOTTOM VIEW ...
Page 100: ... 100 4 SUB P W B ASSEMBLY FMN1260NFM B D TOP VIEW BOTTOM VIEW ...
Page 101: ... 101 Schematic Diagram 1 Indoor Unit FMN0760NL FMN0960NL FMN1260NL FMN1860NL ...
Page 103: ... 103 FMN1260NFM B D ...
Page 104: ... 104 FMN1860NV RY 4WAY RY OUTFAN ...
Page 122: ...P No 3828A20208A August 2002 Printed in Korea ...