3-way Valve (Liguid Side)
3-way Valve (Gas Side)
Works
Shaft position
Shaft position
Service port
Shipping
Closed
Closed
Closed
(with valve cap)
(with valve cap)
(with cap)
Air purging
Open
Closed
Open
(Installation)
(counter-clockwise)
(clockwise)
(push-pin or with
vacuum pump)
Operation
Open
Open
Closed
(with valve cap)
(with valve cap)
(with cap)
Pumping down
Closed
Open
Open
(Transfering)
(clockwise)
(counter-clockwise)
(connected
manifold gauge)
Evacuation
Open
Open
Open
(Servicing)
(with charging
cylinder)
Gas charging
Open
Open
Open
(Servicing)
(with charging
cylinder)
Pressure check
Open
Open
Open
(Servicing)
(with charging
cylinder)
Gas releasing
Open
Open
Open
(Servicing)
(with charging
cylinder)
- 76 -
3-way Valve
3.
2.
1.
4.
5.
6.
Valve cap
To
piping
connection
Open position
Closed position
Pin
Service
port
Service
port cap
To outdoor unit
Hexagonal wrench
(4mm)
To
piping
connection
Pin
Service
port
Service
port cap
To outdoor unit
15.88mm(5/8")
19.05mm(3/4")
Summary of Contents for FMN0760NL
Page 94: ... 94 FMN1260NT FMN1860NT ...
Page 95: ... 95 FMN1260NFM B D TOP VIEW BOTTOM VIEW ...
Page 96: ... 96 FMN1860NV ...
Page 97: ... 97 2 Outdoor Unit MAIN P C B ASM FMU4480N6L ...
Page 98: ... 98 PCB PWB ASSY SUB ...
Page 99: ... 99 3 Display ASSY FMN1860NV FMN1260NFM B D TOP VIEW BOTTOM VIEW ...
Page 100: ... 100 4 SUB P W B ASSEMBLY FMN1260NFM B D TOP VIEW BOTTOM VIEW ...
Page 101: ... 101 Schematic Diagram 1 Indoor Unit FMN0760NL FMN0960NL FMN1260NL FMN1860NL ...
Page 103: ... 103 FMN1260NFM B D ...
Page 104: ... 104 FMN1860NV RY 4WAY RY OUTFAN ...
Page 122: ...P No 3828A20208A August 2002 Printed in Korea ...