4
MULTI/SINGLE CAC
Indoor unit
Console
2. Specifications
Model Name
ZQNW09GALA1
[UQ09F NA0]
ZQNW12GALA1
[UQ12F NA0]
Power Supply
V, Ø, Hz
220-240, 1, 50
220-240, 1, 50
220, 1, 60
220, 1, 60
Power Input
H / M / L
W
37 / 30 / 25
37 / 30 / 25
Running Current
H / M / L
A
0.53 / 0.51 / 0.48
0.53 / 0.51 / 0.48
Max.
A
0.70
0.70
Exterior
Color (RAL Code)
-
Morning Fog (9001)
Morning Fog (9001)
Dimensions
W x H x D
mm
700 × 600 × 210
700 × 600 × 210
Weight
Net
kg
16.3
16.3
Shipping
kg
19.3
19.3
Heat Exchanger
Rows x Columns x FPI
-
2 x 19 x 19
2 x 19 x 19
Face Area
m
2
0.18
0.18
Fan Type
-
Turbo Fan
Turbo Fan
Air Flow Rate
H / M / L
m
3
/min
8.5 / 6.7 / 5.0
8.5 / 6.7 / 5.0
Fan Motor
Type
-
BLDC
BLDC
Drive
-
Internal
Internal
Output
W x No.
48 x 1
48 x 1
Sound Pressure Level
Cooling
H / M / L
dB(A)
38 / 32 / 27
38 / 32 / 27
Heating
H / M / L
dB(A)
38 / 32 / 27
38 / 32 / 27
Sound Power Level
Cooling
Rated
dB(A)
59
59
Heating
Rated
dB(A)
-
-
Piping Connections
Liquid
mm(inch)
Ø 6.35 (1/4)
Ø 6.35 (1/4)
Gas
mm(inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Drain (O.D. / I.D.)
mm
Ø 16.7 / 12.2
Ø 16.7 / 12.2
Safety Devices
-
Fuse
-
Thermal Protector for Fan Motor
Power and Communication Cable (included Earth)
No. x mm
2
(AWG)
4C x 0.75 (18)
4C x 0.75 (18)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national code. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound Level Values are measured at Noise Measuring chamber accordance with standard. Therefore, these values depend on the ambient conditions
and values are normally higher in actual operation(Sound Pressure : LG Internal standard, Sound Power : EN 12102 (ISO 3741).
4. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.