Outdoor Units
Service Manual
131
(4) Compressor Discharge-Temp. Control
After 1 min. of normal control, if it is satisfied with fomula below, it starts to control of Comp. Discharge
Temp.
Cooling mode : The present degree of superheat
≤
3 (Option)
Heating mode : The target degree of superheat < 0 , The present degree of superheat
≤
0 (Option)
The present degree of superheat
≥
0, The present degree of superheat
≤
5 (Option)
❈
The target degree of superheat is decided for indoor_unit and operation mode.
❈
The target Temp. of discharge pipe is decided for indoor_unit, outdoor_unit and Comp operation Step, the
difference indoor and outdoor.
1.4 Fan control
1) STANDARD STEP : Stop, Operation (2 Step)
2) Phase control : The low Temp.of outdoor (=Cooling), The high Temp. of outdoor (=heating)
→
Control fan On/Off, or Decrease the volume of fan's wind.
(1) COOLING
(2) HEATING
Air
circulation FULL SPEED
SPEED SLOPE
(OPTION)
40
%
OFF
SET POINT
: Outdoor Temp.
or
Outdoor pipe Temp.
(OPTION)
Outdoor Fan
OFF Temp.
(OPTION)
Phase control
OFF
Outdoor Fan
ON Temp.
(OPTION)
FULL SPEED
FULL SPEED
OFF
Outdoor Fan
OFF Temp.
or
Outdoor pipe
Temp.
(OPTION)
OFF
Outdoor Fan
OFF Temp.
or
Outdoor pipe
Temp.
(OPTION)
FULL SPEED
Air
circulation
❈
OPTION: Each models have a different establishment.
Summary of Contents for ABNH186HLAC
Page 85: ...Service Manual 89 MPS Variable SINGLE A 4 Wiring Diagrams AUUH126C AUUH186C ...
Page 87: ...Electronic Control Device Service Manual 91 MPS Inverter SINGLE A AUUH368C AUUH488C ...
Page 88: ...92 Universal System Air Conditioner MPS Variable SINGLE A AUUH608C ...
Page 107: ...Electronic Control Device Service Manual 111 Ceiling Duct Type BH Series ...
Page 108: ...Electronic Control Device 112 Universal System Air Conditioner BG BR Series ...
Page 109: ...Electronic Control Device Service Manual 113 VE Series AC DC Ceiling Floor C ...
Page 110: ...Electronic Control Device 114 Universal System Air Conditioner VB VK VL Series ...
Page 113: ...Electronic Control Device Service Manual 117 Schematic Diagram Ceiling Duct Type ...
Page 134: ...Outdoor Units 138 Universal System Air Conditioner ...
Page 175: ...P No 3828A22009P Printed in Korea ...