18
206-4340
EZ-Manager Wizard (Cont.)
(Continued from previous page)
IP Configuration
a) In the Media Type
field,
use the Left/Right arrow keys to select
IP
.
Note:
When you select “IP” as the Media Type, the default (RF) Data Channel and Signal
Strength/Quality fields are replaced with (IP) Address and Port fields.
b)
In the Address and Port fields, either key in or use the Left/Right arrow keys to select the
appropriate values for the Pro:Centric server IP address and port number. The IP address
must match the IPv4 multicast address and the port number must match the port number
that is set in the Pro:Centric server.
4. Once all fields are completed as required, you
have two options:
• To save the data entered and exit the wizard, use the arrow keys to select
Exit
and then press
OK
. In the subsequent pop-up confirmation window, select
Save and Exit
, and then press
OK
once more. The Pro:Centric application and/or E-Z Installation data will be downloaded to the
TV at a later time. This option is useful, in particular, if the Pro:Centric server has not yet been
configured.
• To initiate a real-time download of Pro:Centric application and/or E-Z Installation data, use the
arrow keys to select
Next
, and then press
OK
(see also note below).
Note:
With RF configuration, Pro:Centric server data must be present on the RF channel
selected as the TV’s Data Channel in order for you to select “Next” (you will see a “Data
Channel Found” message below the Signal Quality indicator). With IP configuration,
Pro:Centric server data must be present via the wired LAN cable connection in order for
you to select “Next” (you will see a “IP Server Found” message below the Port field).
If you opt to initiate a real-time download in the last step, the EZ-Manager Wizard will proceed with
the Pro:Centric application and/or E-Z Installation data downloads (see Processing the Pro:Centric
Configuration screen example on page
16).
When the Pro:Centric configuration is complete, an
EZ-Manager Configuration Complete screen (see example on page
10 seconds, the wizard exits, and the TV turns OFF.
Note:
With the EZ-Manager Configuration
Complete screen on display, you also have the option
to manually turn off or reboot the TV. If desired, select
Turn Off
or
Reboot
, respectively, and then
press
OK
on the Installer Remote.
USB Configuration
TV Manager / USB download options
enable you to download configuration
, boot logo (splash
screen) image,
or software files
individually from a USB memory device to the TV. You can also use
the Ez
Download utility available from the menu to select multiple types of files to be downloaded
at one time using one process.
Each of the USB download
functions requires that you have the appropriate file(s) loaded on a USB
memory device. If you wish to perform a software update or download a boot logo, the software/
image file(s) must be stored in a folder named “LG_DTV” in the root directory of the USB device.
Clone/Configuration (.tlx) files should simply be stored in the root directory of the USB device.
The procedure below assumes that the desired file(s) is/are already
loaded onto the USB device.
For further information on TV Manager / USB download options and file requirements, and/or for
information on creating Clone/Configuration (.tlx) files, refer to the appropriate section(s) in this
document.