Maintenance Checklist
Before Operation
□
Visually inspect the semi-automatic capsule filler and the parts.
□
Ensure all nuts and bolts are tight.
□
Visually inspect grease points and regrease where necessary.
□
Run the machine at a slow speed to ensure that everything is operating correctly.
□
Visually inspect electrical wires for any damage.
During Operation
□
Tune the semi-automatic capsule filler until the capsule fill and weight are correct.
□
Listen for irregular knocking or clicking sounds. If heard, stop operation, dislodge any
stuck capsules from the machine, adjust the Capsule Holding Pins, and lubricate the
machine.
□
Watch for buildup of powder on the Auger inside the Powder Hopper. If occurring, either (a)
make mix more granular, (b) check the Auger for damage, or (c) clear the buildup.
□
Occasionally check the Motor's temperature. If it starts to overheat, turn o
ff
the machine, let
it cool down, and grease it to ensure smooth operation.
□
Ensure that the Hoppers do not run out of powder and capsules.
□
Weigh five or ten sample capsules to ensure the desired weight and fill are being met.
□
Check to see that the Emergency Stop properly works.
After Operation
□
Unplug machine and remove all excess powder with a bagless vacuum.
□
Clean the Capsule Hopper, the Powder Hopper, the Capsule Magazine and teeth, the
Capsule Discs, the Capsule Ejection Disc, and the Auger.
□
Wipe down the other surfaces with a damp cloth.
□
Lubricate all grease points.
□
Store Tooling in a container with a small amount of grease.