![LFA SACF 25 User Manual Download Page 40](http://html1.mh-extra.com/html/lfa/sacf-25/sacf-25_user-manual_1891162040.webp)
40
Wear Parts and Causes of Damage
Wear Part
Cause of Damage
Capsule Discs
The Capsule Discs on the SACF 25
®
hold the capsule bodies
and caps while they are being filled. It would be a good idea to
have spare a Capsule Disc to increase production capacities
and in the event of a damaged occuring during cleaning or
mishandling.
Teflon Wear Part on Vacuum Section
This wear part sits between the vacuum section and on the
main body of the machine and the Capsule Discs when the
capsules are being sewn. This part is prone to wear over time
because it maintains a seal between the disc and the vacuum.
If the seal becomes less tight, it could result in capsules not
separating properly.
Teflon Wear Part on Bottom of Auger
This wear part sits between the Powder Hopper with its auger
and the Capsule Disc that holds the capsule bodies that are
being filled. This part is prone to wear over time because
it maintains a seal between the plate and the auger, and a
powder leak would result from this worn part.
Capsule Holding Pins
The Capsule Holding Pins hold the capsules in the cartridge
and time their release. In the event of a jam, during cleaning, or
mishandling, they can become damaged.