![LFA SACF 25 User Manual Download Page 52](http://html1.mh-extra.com/html/lfa/sacf-25/sacf-25_user-manual_1891162052.webp)
52
Auger Teflon Wear Part
Tools and Materials Needed
• 13 mm wrench
• Crosshead screwdriver
• New Auger teflon wear part
• Disposable latex/rubber gloves (for food grade products and to protect hands from grease)
• Hairnet and/or beard net (food grade products only)
• Sterile shoe covers (food grade products only)
This wear part sits between the Auger and the Capsule Disc that holds the capsule bodies that are
being filled. It maintains a seal between the plate and the Auger.
Instructions
Note: Wear latex/rubber gloves (and appropriate food grade attire if applicable) during this
process.
WARNING:
To prevent any potential personal injury, ALWAYS unplug the SACF 25
®
from the electrical outlet when replacing parts.
Remove the Auger Teflon Wear Part
1. Loosen the Powder Hopper's bolts with a 13 mm wrench.