70
Method 2: Clean Excess Powder Buildup
1. Remove the Capsule Hopper, the Powder Hopper, the Capsule Magazine and teeth, the Capsule
Discs, the Capsule Ejection Disc, and the Auger.
1.1 Note: Please refer to the remove and replace Tooling instructions on page 41
for
further assistance and the remove and replace Auger Teflon Wear Part instructions
on page 52 for further assistance.
2. Take one of the parts removed from the machine and bring it to the bowl of soapy water.
2.1 Note: To ensure that all dirt and debris are removed, wash one part at a time.
3. Take a clean cloth and carefully wash the part thoroughly.
3.1 Note: Use the toothbrush for di
ffi
cult-to-remove debris. When cleaning Tooling, use
non-abrasive cleaning equipment such as a soft pipe cleaner and soft cloth.
4. Dry part immediately after it is cleaned and rinsed.
5. Sanitize part with a clean cloth.
6. Repeat steps 2-6 for each remaining part until they are all clean.
Method 3: Realign the Capsule Holding Pins
1. Remove the Capsule Hopper and the Capsule Magazine and its teeth.
1.1 Note: Please refer to the remove and replace Capsule Holding Pins instructions on page
56
for further assistance.
2. Remove the Capsule Holding Pins' screws with a crosshead screwdriver.
3. Adjust the Capsule Holding Pins until they are all straight and correctly aligned.