![LFA SACF 25 User Manual Download Page 27](http://html1.mh-extra.com/html/lfa/sacf-25/sacf-25_user-manual_1891162027.webp)
27
Auger Fill Amount Time
Whenever the Capsule Disc's rotation speed is decreased, the Auger fill amount time has to be
increased. This will make sure that there is enough time for the Capsule Disc to fully rotate under
the Auger.
Tools and Materials Needed
• Disposable latex/rubber gloves (for food grade products and to protect hands from grease)
• Hairnet and/or beard net (food grade products only)
• Sterile shoe covers (food grade products only)
Instructions
Note: Wear latex/rubber gloves (and appropriate food grade attire if applicable) during this process.
1. Run the Auger to determine the adjustment.
2. Press the button with the arrow facing in the right direction until the COUNTING OF FILLING
display is blinking.
3. Press the up/down arrow areas on the buttons to adjust the amount of seconds the Auger will
operate.
3.1 Note: Press the CLR areas on the buttons to clear the amount entirely.
4. Press the SET area button after the adjustment is made.