![LFA SACF 25 User Manual Download Page 41](http://html1.mh-extra.com/html/lfa/sacf-25/sacf-25_user-manual_1891162041.webp)
41
Tooling
Tools and Materials Needed
• Set of metric Allen keys with ball ends
• 24 mm wrench
• Tooling (New Capsule Discs, Capsule Magazine, and Capsule Ejection Disc)
• Alignment Tools from SACF 25
®
Toolkit
• Empty capsules suited for new Tooling
• Disposable latex/rubber gloves (for food grade products and to protect hands from grease)
• Hairnet and/or beard net (food grade products only)
• Sterile shoe covers (food grade products only)
If you want to change size of a capsule, or if the Capsule Discs you currently have are damaged, it
is necessary to change the Tooling.
To buy new Tooling from LFA, simply go to
https://www.lfacapsulefillers.com/sacf25-plates-moulds-
set
To watch a video of a SACF 25
®
Tooling change, go to
https://www.lfacapsulefillers.com/sacf-
tooling-change
Remove the Old Tooling
1. Remove the Perspex Covers from the top of the Capsule Hopper and the Capsule Sewing
Repository.
Instructions
Note: Wear latex/rubber gloves (and appropriate food grade attire if applicable) during this process.
WARNING:
To prevent any potential personal injury, ALWAYS unplug the SACF 25
®
from the electrical outlet when replacing parts.
2. Ensure that the Capsule Hopper Gate is fully closed.