![Leuze MLC 530 SPG Original Operating Instructions Download Page 86](http://html.mh-extra.com/html/leuze/mlc-530-spg/mlc-530-spg_original-operating-instructions_1883795086.webp)
Troubleshooting
Leuze electronic GmbH + Co. KG
MLC 530 SPG
86
Error
Cause/description
Measures
Sensor behavior
E03
Overload on OSSD2
Check the wiring or exchange the
connected component (reducing
the load).
OSSD switches off
E04
High-impedance short circuit to
VCC OSSD1
Check the wiring. Exchange the
cable, if applicable.
OSSD switches off
E05
High-impedance short circuit to
VCC OSSD2
Check the wiring. Exchange the
cable, if applicable.
OSSD switches off
E06
Short circuit against GND at
OSSD1
Check the wiring. Exchange the
cable, if applicable.
OSSD switches off
E07
Short circuit a24 V at
OSSD1
Check the wiring. Exchange the
cable, if applicable.
OSSD switches off
E08
Short circuit against GND at
OSSD2
Check the wiring. Exchange the
cable, if applicable.
OSSD switches off
E09
Short circuit a24 V at
OSSD2
Check the wiring. Exchange the
cable, if applicable.
OSSD switches off
E10, E11
OSSD error, source unknown
Check the wiring. Exchange the
cable and the receiver if neces-
sary.
OSSD switches off
E14
Undervoltage (< +15 V)
Supply the device with the correct
voltage.
OSSD switches off
E15
Overvoltage (> +32 V)
Supply the device with the correct
voltage.
OSSD switches off
E16
Overvoltage (> +40 V)
Supply the device with the correct
voltage.
Locking
E18
Ambient temperature too high
Ensure correct environmental con-
ditions
OSSD switches off
E19
Ambient temperature too low
Ensure correct environmental con-
ditions
OSSD switches off
E22
Interference detected on plug
pin 3. Signal output: output sig-
nal is not equal to the signal in-
put read-back value: it
switches simultaneously with
the other signal line.
Check the wiring.
OSSD switches off
E23
Interference detected on plug
pin 4. Signal output: output sig-
nal is not equal to the signal in-
put read-back value: it
switches simultaneously with
the other signal line.
Check the wiring.
OSSD switches off
E24
Interference detected on plug
pin 8. Signal output: output sig-
nal is not equal to the signal in-
put read-back value: it
switches simultaneously with
the other signal line.
Check the wiring.
OSSD switches off
E39
Actuation duration (2.5 min)
exceeded for reset button or
cable short circuited
Press the reset button. If the
restart is unsuccessful, check the
wiring of the reset button.
OSSD switches off