![Leuze MLC 530 SPG Original Operating Instructions Download Page 60](http://html.mh-extra.com/html/leuze/mlc-530-spg/mlc-530-spg_original-operating-instructions_1883795060.webp)
Mounting
Leuze electronic GmbH + Co. KG
MLC 530 SPG
60
7.1.6
Preventing mutual interference between adjacent devices
If a receiver is located in the beam path of an adjacent transmitter, optical crosstalk, and thus erroneous
switching and failure of the protective function, may result.
1
2
3
4
1
Transmitter 1
2
Receiver 1
3
Transmitter 2
4
Receiver 2
Fig. 7.4:
Optical crosstalk between adjacent safety sensors (transmitter 1 influences receiver 2) due to incorrect
mounting
NOTICE
Possible impairment of the availability due to systems mounted close to each other!
The transmitter of one system can influence the receiver of the other system.
Ä
Prevent optical crosstalk between adjacent devices.
Ä
Mount adjacent devices with a shield between them or install a dividing wall to prevent mutual interfer-
ence.