Configuration control
Leuze electronic
DCR 50
33
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Korean Post
SY
KOP
O
S/P/R/
G
EN
0
0
Disable
Example:
SYKOPOSEN0
1
Enable
Example:
SYKOPOSEN1
Matrix 2 of 5
SY
M2O
5
S/P/R/
G
EN
0
0
Disable
Example:
SYM2O5SEN0
1
Enable
Example:
SYM2O5SEN1
Maxicode
SY
MAX
C
S/P/R/
G
EN
0
0
Disable
Example:
SYMAXCSEN0
1
Enable
Example:
SYMAXCSEN1
MSI Plessey – Get All
Parameter
SY
MSIP G
Returns all MSI Plessey parameter val-
ues in an XML element.
Example
: SYMSIPG
MSI Plessey
SY
MSIP S/P/R/
G
EN
0
0
Disable
Example:
SYMSIPSEN0
1
Enable
Example:
SYMSIPSEN1
MSI Plessey – Require
Checksum
SY
MSIP S/P/R/
G
CS
0
0
Disable
Example:
SYMSIPSCS0
1
Enable
Example:
SYMSIPSCS1
2
10/10 Checksum type
Example:
SYMSIPSCS2
3
11/10 Checksum type
Example:
SYMSIPSCS3
Note:
This setting value is ignored if MSI
Plessey decoding is disabled.
MSI Plessey – Strip
Checksum
SY
MSIP S/P/R/
G
SC
0
0
Disable
Example:
SYMSIPSSC0
1
Enable
Example:
SYMSIPSSC1
Note:
This setting value is ignored if MSI
Plessey decoding is disabled.
Plessey – PLE
SY
MSIP S/P/R/
G
PE
0
0
Disable
Example:
SYMSIPSPE0
1
Enable
Example:
SYMSIPSPE1
NEC 2 of 5 – Get All Pa-
rameter
SY
N2O
5
G
Returns all NEC 2 of 5 parameter values
in an XML element.
Example
: SYN2O5G