Configuration control
Leuze electronic
DCR 50
36
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
QR Code – Mode 1
SY
QRC
O
S/P/R/
G
M1
0
0
Disable
Example:
SYQRCOSM10
1
Enable
Example:
SYQRCOSM11
Note:
This setting value is ignored if QR
Code decoding is disabled.
QR Code – Custom
SY
QRC
O
S/P/R/
G
CQ
0
0
Disable
Example:
SYQRCOSCQ0
1
Enable
Example:
SYQRCOSCQ1
Note:
This setting value is ignored if QR
Code decoding is disabled.
Straight 2 of 5
SY
S2O5 S/P/R/
G
EN
0
0
Disable
Example:
SYS2O5SEN0
1
Enable
Example:
SYS2O5SEN1
Telepen – Get All Pa-
rameter
SY
TELP G
Returns all Telepen parameter values in
an XML element.
Example
: SYTELPG
Telepen
SY
TELP S/P/R/
G
EN
0
0
Disable
Example:
SYTELPSEN0
1
Enable
Example:
SYTELPSEN1
Telepen – Ouput ASCII
SY
TELP S/P/R/
G
OA
0
0
Disable
Example:
SYTELPSOA0
1
Enable
Example:
SYTELPSOA1
Note:
This setting value is ignored if
Telepen decoding is disabled.
Trioptic – Get All Param-
eter
SY
TRIO G
Returns all Trioptic parameter values in
an XML element.
Example
: SYTRIOG
Trioptic
SY
TRIO S/P/R/
G
EN
0
0
Disable
Example:
SYTRIOSEN0
1
Enable
Example:
SYTRIOSEN1
Trioptic – Reverse
SY
TRIO S/P/R/
G
RV
0
0
Disable
Example:
SYTRIOSRV0
1
Enable
Example:
SYTRIOSRV1
Note:
This setting value is ignored if Tri-
optic decoding is disabled.