Configuration control
Leuze electronic
DCR 50
37
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Trioptic – Start/Stop
SY
TRIO S/P/R/
G
SS
0
0
Disable
Example:
SYTRIOSSS0
1
Enable
Example:
SYTRIOSSS1
Note:
This setting value is ignored if Tri-
optic decoding is disabled.
UK Royal Mail
SY
UKR
O
S/P/R/
G
EN
0
0
Disable
Example:
SYUKROSEN0
1
Enable
Example:
SYUKROSEN1
UK Royal Mail – Require
Check Character
SY
UKR
O
S/P/R/
G
CC
0
0
Disable
Example:
SYUKROSCC0
1
Enable
Example:
SYUKROSCC1
Note:
This setting value is ignored if UK
Royal Mail decoding is disabled.
UPC/EAN – Get All Pa-
rameter
SY
UPC
0
G
Returns all UPC/EAN parameter values
in an XML element.
Example
: SYUPC0G
UPC/EAN
SY
UPC
0
S/P/R/
G
EN
1/0
0
Disable
Example:
SYUPC0SEN0
1
Enable
Example:
SYUPC0SEN1
UPC/EAN – Expand
UPC-E to UPC-A
SY
UPC
0
S/P/R/
G
EA
1
0
Disable
Example:
SYUPC0SEA0
1
Enable
Example:
SYUPC0SEA1
Note:
This setting value is ignored if
UPC/EAN decoding is disabled.
UPC/EAN – Supplemen-
tal
SY
UPC
0
S/P/R/
G
SU
0
0
Disable
Example:
SYUPC0SSU0
1
Enable
Example:
SYUPC0SSU1
Note:
This setting value is ignored if
UPC/EAN decoding is disabled.
UPC/EAN – Expand
EAN-8 to EAN-13
SY
UPC
0
S/P/R/
G
8D
0
0
Disable
Example:
SYUPC0S8D0
1
Enable
Example:
SYUPC0S8D1
Note:
This setting value is ignored if
UPC/EAN decoding is disabled.