Configuration control
Leuze electronic
DCR 50
53
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Echo option
FW CM
S/P/R/
G
OE
0
0
Disable Raw Command Echoing
Example
: FWCMSOE0
1
Enable Raw Command Echoing
Example
: FWCMSOE1
Raw Command Enable
FW CM
S/P/R/
G
OR 0
0
Disable Raw Commands
Example
: FWCMSOR0
1
Enable Raw commands
Example
: FWCMSOR1
8.2.10 General reader feedback parameters
Code Description
Command Format Op-
tions
Default Notes/Examples
Get All Reader Feedback
Parameters
FB
FB
G
Returns all Reader Feedback parameter
values in an XML element.
Example
: FBFBG
Good Read Indication – Fre-
quency (Hz)
FB
GR
S/P/R/
G
FQ
2400
Good read beep output frequency.
Valid Range:
Example
: FBGRSFQ2400
Good Read Indication –
Beep Volume (percent)
FB
GR
S/P/R/
G
VO
100
Valid Range:
0 to 100 percent
Example
: FBGRSVO100
Good Read Indication –
Beep As IO
FB
GR
S/P/R/
G
BI
0
0
Good Read Indication is a fre-
quency output as defined by FB-
GRGFQ
Example
: FBGRSBI0
1
Good Read Indication is an IO
signal
Example
: FBGRSBI1
8.2.11 Setup default AGC mode
Code Description
Command Format Op-
tions
Default Notes/Examples
Get All Scene Manager Pa-
rameters
SC
SC
G
Returns all Scene Manager parameter
values in an XML element.
Example
: SCSCG
Scene Manager Mode
SC
SP
S/P/R/
G
MO NO
NO
Normal AGC Mode
Example
: SCSPSMONO
BY
Bypass AGC Mode
Example
: SCSPSMOBY
FX
Fixed AGC Mode
Example
: SCSPSMOFX