Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 92
38
7.3
Starting up with factory settings
Ä
Connect the operating voltage (+10 … 30 V DC).
Ä
If applicable, connect the switching input and the RS 232 interface.
Ä
Switch on the operating voltage. The status LED must illuminate green.
Ä
Activate the bar code reader via the switching input or with the
‘+‘
online command. The laser switches
itself on.
Ä
Hold the following sample bar code up to the bar code reader at a distance of approx. 100 mm.
Ä
If reading is successful, the laser switches off. The read result is displayed on the monitor of the con-
nected device.
Ä
Deactivate the reading gate by removing the switching input signal or with the
‘-‘
online command.
7.4
Setting the configuration parameters
You commissioned the device. Usually, you will have to configure it before you can use it. With the configu-
ration possibilities offered by the
Sensor Studio
configuration software or the device DTM, you can individu-
ally adapt the device to your specific application. For instructions regarding the various setting options, re-
fer to the online help or to the see chapter 6.5 "Configuration parameters".
• To operate the bar code reader, it is normally sufficient to set code type and code length in accordance
with the bar codes that are to be read.
• Depending on the application, you can configure the switching input according to your requirements.
Configuration settings
The configuration settings are stored in the memory of the bar code reader in parameter sets. The various
parameter sets are explained to understand what is happening during configuration parameter setting (see
chapter 7.4.2 "Parameter sets").
• The setting of code type and code length is usually accomplished by using the
Sensor Studio
configu-
ration software (see chapter 6 "Configuration and diagnostics software - Sensor Studio").
• You can set other configuration parameters as follows:
• Via the
Sensor Studio
configuration software with the buttons located under
CONFIGURATION
.
• Via the internal setup of the bar code reader (start with the online command
CA
• Via online commands (see chapter 8.4 "Online commands for the parameter set operations").