Online commands
Leuze electronic GmbH + Co. KG
BCL 92
43
autoConfig
Command
’CA’
Description
Activates or deactivates the
autoConfig
function. Certain bar code recognition
parameters are programmed automatically in the setup by the bar code labels
which the device reads while the
’
autoConfig’ function is active.
Parameter
’+’
Activates ’autoConfig’
’/’
Rejects the last code read
’-’
Deactivates ’autoConfig’ and stores the decoded data in the
current parameter set
Acknowledgment
’CSx’
x
Status
’0’
valid ’CA’ command
’1’
Invalid command
’2’
’autoConfig’ could not be activated
’3’
’autoConfig’ could not be deactivated
’4’
Result could not be deleted
Description
’xx yy zzzzzz’
xx
Code type of the read code
’01’
2/5 Interleaved
’02’
Code 39
’03’
Code 32
’06’
UPC-A / UPC-E
’07’
EAN-8 / EAN-13
’08’
Code 128, EAN 128
’09’
Pharmacode
’10’
EAN Addendum
’11’
Codabar
’12’
Code 93
yy
Number of digits of the read code
zzzzzz
Contents of the decoded label. A ↑ appears if the label was
not correctly read.