Technical data
Leuze electronic GmbH + Co. KG
BCL 92
56
Tab. 12.6:
Environmental data
Ambient temperature
Operation
Storage
+5 °C … +40 °C
-20 °C … +60 °C
Air humidity
Max. 90% rel. humidity, non-condensing
Electromagnetic compatibility
EN 61326-1:2013-01,
FCC 15-CFR 47 Part 15 (09-07-2015) Limits Class B
Vibration
IEC 60068-2-6, test Fc
Shock
IEC 60068-2-27, test Ea
Certifications
UL 60950-1, CAN/CSA C22.2 No. 60950-1-07
Conformity
CE, CDRH, UL
12.2
Reading fields
NOTICE
Please note that the actual reading fields are also influenced by factors such as labeling mate-
rial, printing quality, scanning angle, printing contrast etc., and may thus deviate from the read-
ing fields specified here. The origin of the read distance always refers to the front edge of the
housing of the beam exit.
Tab. 12.7:
Reading conditions for the reading field curves
Bar code type
Code type
2/5 Interleaved
Ratio
1:2.5
ANSI specification
Class A
Reading quality
> 75%