Configuration and diagnostics software - Sensor Studio
Leuze electronic GmbH + Co. KG
BCL 92
29
6.5.3
Control tab
Fig. 6.7:
Control
tab
Activation
Switching input 1
Function
See menu
switching input
Auto-start after decoding
Autostart after decode
In this mode, the scanner reads via an internal trigger signal with
maximum performance.
Note
: Up to 100 codes per second can be transmitted.
Command character
The standard online character for the trigger start is the ´+´ character.
The character cannot be changed.
Decode delay time
After the time set here has passed, the scanner automatically reacti-
vates itself following a reading gate end (e.g. in combination with Au-
tostart after decode). Is normally used for test purposes.
Deactivation
Switching input 1
Function
See menu
switching input
Immediately after the complete de-
coding result is available
If the setting is activated, the read result is output immediately after
the bar code is decoded.
If the setting is deactivated, the read result is sent only after the trig-
ger signal is returned (= end of reading gate).
Command character
The standard online character for the trigger end is the ´-´ character.
The character cannot be changed.
Time
If the code reader is activated, the reading gate is automatically
closed by the code reader after this preset time has elapsed (e.g. for
test purposes).
Scans without info
Following a successful read, the code reader waits for this number of
scans (sequential scans with no read result) before it automatically
deactivates itself.