Configuration and diagnostics software - Sensor Studio
Leuze electronic GmbH + Co. KG
BCL 92
35
6.6
Diagnosis
Fig. 6.14:
Diagnosis
tab
On the
Diagnosis
tab, you can send online commands to the device see chapter 8 "Online commands" as
well as display the read results and the device status.
Furthermore, buttons are available for the following functions:
• Layout of the screen display
• Deleting and printing the screen content
• General terminal settings
Version
Requests device version information (see chapter 8.2 "General online com-
mands", command "V").
You can use this command to check whether the communication between
PC and scanner is functional. If you do not receive an acknowledgment,
please check the interface connections or the protocol.
Device Identification
Query of the serial number as well as the hardware and software versions.
Reset
Carries out a software reset. The device is restarted and reinitialized, leav-
ing it in the same state as when the operating voltage is switched on.
Factory Default
Activates the device with the factory settings.
Activate Decoding
Deactivate Decoding
Activates/deactivates decoding.
Start Continuous Decoding
Stop Continuous Decoding
Starts/stops continuous decoding.