background image

Leuze

electronic

VisionREADER 2300
with integrated Decoder

Technical Description

Summary of Contents for VisionREADER 2300

Page 1: ...Leuze electronic VisionREADER 2300 with integrated Decoder Technical Description...

Page 2: ...eserved especially the right of reproduction distribution and translation Copying or reproductions in any form require the written consent of the manufacturer Changes reflecting technical improvements...

Page 3: ...iew 10 4 4 2 Optics variants and reading fields 10 5 Accessories Order Designation 13 5 1 Accessories 13 5 1 1 Connector units 13 5 1 2 Fastening Accessories 15 5 1 3 Connection cable 15 6 Installatio...

Page 4: ...42 9 3 9 EAN13 UPC A EAN8 UPC E 43 9 3 10 Interleaved 2 of 5 44 9 3 11 Code 39 window 45 9 3 12 Code 128 window 46 9 3 13 Codabar window 47 9 3 14 Code 11 window 48 9 3 15 Camera window 49 9 3 16 Com...

Page 5: ...ice name plate VR 2300 16 Figure 6 2 Mounting example VR 2300 17 Figure 6 3 VR 2300 Sub D pin assignments 19 Table 6 1 Wiring description VR 2300 20 Figure 6 4 Connection diagram switching inputs and...

Page 6: ...otice This symbol indicates text passages containing important information 1 2 Declaration of Conformity The code reader VR 2300 and the optional connector units MA 2 and MA 2 L have been developed an...

Page 7: ...y scanners with integrated decoders for Data Matrix Code ECC 200 and all current bar codes used for automatic object recognition The optional connector and interface units MA 2 and MA 2 L are intended...

Page 8: ...this operating manual is not authorised Safety regulations Observe the locally applicable legal regulations and the rules of the employer s liability insur ance association Qualified personnel Mounti...

Page 9: ...ed spaces Information on technical data and characteristics can be found in chapter 4 3 2 Standalone operation The code reader VR 2300 is operated as a stand alone device The VR features a 15 pin sub...

Page 10: ...ead distance 10 150mm 40 172mm Electrical data Interface type RS 232 Host for code output Connections 2 electrically insulated inputs 2 electrically insulated outputs Trigger serial or digital input O...

Page 11: ...uze electronic Specifications Leuze electronic VR 2300 9 TNT 35 7 24V 4 3 Dimensioned drawings VR 2300 Figure 4 1 Dimensioned drawing VR 2300 A For screw M6 x 8 B 15 pin sub D connector C LED green re...

Page 12: ...canning curves for ratings 4 4 1 Type overview Table 4 2 Type overview 4 4 2 Optics variants and reading fields The VR 2300 is available with two different optics The optics differ in range and resolu...

Page 13: ...24V Scanning curves VR 2300 with optic M Figure 4 2 Reading field optics model M medium density normal range 50 mil 1 27 mm 30 mil 0 76 mm 20 mil 0 51 mm 10 mil 0 25 mm 20 2050 30 10 10 30 50 focus 55...

Page 14: ...curves VR 2300 with optic F Figure 4 3 Reading field optics model F low density long range 50 mil 1 27 mm 30 mil 0 76 mm 20 mil 0 51 mm 10 mil 0 25 mm 6 mil 0 15 mm 20 7 0 0 20 40 60 80 20 40 60 80 20...

Page 15: ...t interface RS 232 MA 2 L 500 36186 Connector unit MA 2 L for VR 2300 L design stand alone with host interface RS 232 MA 42 DP k 500 35298 Connector unit MA 42 DP k for VR 2300 at Profibus DP MA 42 IS...

Page 16: ...mpared to the installation of the VR 2300 as a standalone device Terminals for switching inputs and outputs including supply voltage 9 pin sub D plug for service interface Operating mode switch servic...

Page 17: ...signed for rod instal lation Mounting device BT 56 Figure 5 2 Mounting device BT 56 5 1 3 Connection cable Specific connection cables in various lengths are available for the connection between VR and...

Page 18: ...ity device type and model as indicated on the nameplate accessories operating manual The name plate provides information as to what VR type your device is For specific infor mation please refer to cha...

Page 19: ...types of mounting arrangements for the VR 2300 using the dovetail groove and the corresponding mounting accessories see figure 6 2 using the fastening threads on the back and underside of the devices...

Page 20: ...location several factors must be considered size orientation and position tolerance of the codes on the objects to be scanned the reading field of the VR 2300 in relation to the code module width res...

Page 21: ...the generation of the supply voltage for the VR 2300 and the re spective connector units must have a secure electrical insulation through double insulation and safety transformers according to DIN VD...

Page 22: ...st interface RS 232 Pin 4 RTS RTS signal host interface RS232 Pin 5 Res Reserved Pin 6 SWOUT2 Switching output 2 max 100mA Pin 7 Res Reserved Pin 8 VIN Supply voltage 10 30VDC Pin 9 SWIN2 Switching in...

Page 23: ...you can trigger a reading action via the switching input connections SWIN1 SWIN2 by applying a voltage of 12 30VDC between SWIN1 pin 2 or SWIN2 pin 9 and GND pin 15 Switching outputs The switching out...

Page 24: ...or later reuse the device is to be packed so that it is protected against shocks and damp ness Optimal protection is achieved when using the original packaging Notice Electrical scrap is a special was...

Page 25: ...d a problem persist after checking all electrical connections and settings on the devices and host please contact a Leuze service office near you see the back page of this operating manual 7 3 Setting...

Page 26: ...fault settings is loaded into the memory of the VR 2300 the first time the device is commissioned after delivery following the command Default in the parameterisation program if the checksums of the c...

Page 27: ...e figure 7 1 Connection of the service interface VR 2300 standalone Figure 7 1 Connecting the service interface of the VR 2300 to a PC terminal If the VR 2300 is connected to a connector unit MA 2 or...

Page 28: ...which do not effect the proper functioning of the device Serious errors Serious errors impair the proper functioning of the device The device must be reinitialised Troubleshooting Isolated warnings c...

Page 29: ...R Setup Tool software 9 1 Installing the VisionREADER software If there is no Java Runtime Environment Version 1 4 or higher present on your PC you have to install this first Insert the Installation C...

Page 30: ...onic Installation directory Figure 9 2 Installation directory Confirm your entry with Continue and follow the installation routine Browser selection Figure 9 3 Browser selection Select the browser you...

Page 31: ...with the Device Leuze electronic VR 2300 29 TNT 35 7 24V Installing the VisionREADER software Figure 9 4 Installing the VisionREADER software Copy the VSST directory from the Installation CD ROM onto...

Page 32: ...e by double clicking on the file vsst jar in the VSST directory on your hard disk Select the COM interface that connects your PC to the VR 2300 and click on Connect We recommend selection of the highe...

Page 33: ...rameter set permanently to the EEP ROM of the VR 2300 Attention Without Apply all parameter changes are lost if the voltage supply is interrupted Configuration Open Loads a parameter set from a file i...

Page 34: ...efault parameters when a firmware update is performed we recom mend that you save the parameters before the update proc ess A notification window reminds you of this Serial Trigger On Activates a trig...

Page 35: ...e configuration of the VR 2300 easier for you the Setup Tool features different panels On the one hand you can configure the code reading processes and set the camera prop erties On the other hand you...

Page 36: ...ick on the corresponding folder This panel displays information regarding the serial number and the type of the reading system Activate the checkbox Show extended serial number to obtain additional in...

Page 37: ...24V 9 3 2 Info Software panel In order to display the Software panel double click on the Info folder and then on the respective item This panel informs you about the versions of the software firmware...

Page 38: ...euze electronic 9 3 3 Info Hardware panel In order to display the Hardware panel double click on the Info folder and then on the respective item This panel shows information about the hardware compone...

Page 39: ...trans fer the image size can be reduced by the factors specified here Image format Defines the image format The formats supported are bitmap and jpeg Image quality The image quality can be set here if...

Page 40: ...n order to display the Decoder panel double click on the Data Matrix folder and then on the respective item On this panel you can carry out various settings regarding the decoding strategy for Data Ma...

Page 41: ...shold that applies to the entire image to detect the grey scale edges Gavisync finding the threshold for binarisation using the Gavisync algorithm This is the option we recommend Threshold permits the...

Page 42: ...quadratic symbols will be read The remaining selection options specify a single symbol size e g 16 x 16 Symbol orientation The software detects the code orientation automatically The setting 0 DEGREE...

Page 43: ...bar code window Bar code decoding is switched on by selecting on the Enabled button on the 1D Barcode main window Further parameterisation is performed in the sub window 1D Barcode Decoder The single...

Page 44: ...lectronic 42 VR 2300 Leuze electronic 9 3 8 Decoder window The settings in this window are valid for all 1D bar code types Parameter Description Inverse decoding Enables additional decoding of inverte...

Page 45: ...ription Enabled Enables the decoding of EAN13 UPC A EAN8 and UPC E bar codes Decode add on The 2 or 5 digit extension is output e g pricing information for magazines The extension is appended behind t...

Page 46: ...les the decoding of Interleaved 2 of 5 bar codes Check character The VR 2300 only outputs Interleaved 2 of 5 bar codes with a valid check character Code size Only Interleaved 2 of 5 bar codes that con...

Page 47: ...coding of Code 39 bar codes Check character The VR 2300 only outputs Code 39 bar codes with a valid check char acter Extended Code 39 Extended full ASCII is enabled for decoding Codesize Only Code 39...

Page 48: ...Communicating with the Device Leuze electronic 46 VR 2300 Leuze electronic 9 3 12 Code 128 window Parameter Description Enabled Enables the decoding of Code 128 bar codes...

Page 49: ...Leuze electronic Communicating with the Device Leuze electronic VR 2300 47 TNT 35 7 24V 9 3 13 Codabar window Parameter Description Enabled Enables the decoding of Codabar bar codes...

Page 50: ...uze electronic 48 VR 2300 Leuze electronic 9 3 14 Code 11 window Parameter Description Enabled Enables the decoding of Code 11 bar codes Two check characters The VR 2300 only outputs Code 11 bar codes...

Page 51: ...es the value set here Gain variation Causes a variation in the brightness amplification For this purpose the Gain value in the positive and negative direction is changed by the amount specified here A...

Page 52: ...ls Vertical size Allows the camera image to be truncated in the y direction in order to save reading time Illumination Describes the illumination control Off turns the illumination off permanently On...

Page 53: ...s COM1 COM2 and Ethernet Notice For the VR 2300 only the COM1 interface in connection with GModem protocol is suitable as a setup interface Setup protocol Determines the protocol that handles the comm...

Page 54: ...At the start of the window the digital outputs Code read Code not read are reset After a successful read or at the end of the reading window the result is presented at the respective output Time fram...

Page 55: ...the size of the image memory from one up to 12 images at a resolution of 800x600 pixels and up to 50 images at a resolution of 400x300 pixels In combination with the adjustable trigger mode Image str...

Page 56: ...baud rate Parity Enables the detection of transmission errors by means of an additionally inserted parity bit If the parity is None no parity bit is added The setting Even adds an odd parity the sett...

Page 57: ...ation Interfaces GSM Modem window The GSM Modem panel is used to administer a potentially connected GSM modem not possible with the VR 2300 Notice This functionality is not available for the VR 2300 9...

Page 58: ...ated in the Communication panel see chapter 9 3 16 Dynamic IP address Lets the VR 2300 obtain its IP address from its communication counterpart provided the counterpart is able to supply it In the cas...

Page 59: ...ocols PPP window The PPP panel is used to register the VR 2300 with a PPP server Notice In order to be able to perform settings in this panel the protocol PPP must be activated in the Communication pa...

Page 60: ...n Header Allows the selection of seven characters that are output before the actual code content The characters may be input as ASCII characters special characters may be entered in three digit octal...

Page 61: ...and terminator during transmission Trigger off command Defines the character string that terminates a serial trigger The string must not be longer than 7 characters and must be framed by header and t...

Page 62: ...nds Parameter Description Time PC system time Code Data contents of the code Cpx Code centre X co ordinate in pixels Cpy Code centre Y co ordinate in pixels Siz Code size in percent of the image Ctr C...

Page 63: ...chapter 9 3 4 on page 37 the Snapshot function see chapter 9 2 1 description of the menu items on page 31 opens a window whose right side shows an individual image from the camera This image can be a...

Page 64: ...de contents If a Data Matrix Code is read the code content is written into the image with red colour at the L peripheral Within the image itself the right mouse button can be used to specify the zoom...

Page 65: ......

Page 66: ...com IVO Leuze Vogtle Malanca s r l Tel Int 39 02 26110643 Fax Int 39 02 26110640 E mail ivoleuze tin it http www ivoleuze com Galoz electronics Ltd Tel Int 972 0 3 9023456 Fax Int 972 0 3 9021990 E ma...