Configuration control
Leuze electronic
DCR 55
42
8.2.2
Communications
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Get All Communications
Parameters
CM CM
G
Example: CMCMG
Communications Mode
CM MO
S/P/R/
G
CM UK
SE
RS-232 Serial
Example:
CMMOSCMSE
UK
USB Keyboard
Example:
CMMOSCMUK
UV
USB VCOM
Example:
CMMOSCMUV
UN
USB Native
Example:
CMMOSCMUN
UP
USB HID POS
Example:
CMMOSCMUP
UC
USB CDC VCOM
Example:
CMMOSCMUC
Communication Protocol
CM CP
S/P/R/
G
PM 0
0
Raw Mode
Example:
CMCPSPM0
1
Packet Mode
Example:
CMCPSPM1
Connection Retry Timeout
(s)
CM GE
S/P/R/
G
CR 5000
If reader disconnects, it will try to recon-
nect after the timeout interval in seconds.
Valid Range:
Example
: CMGESCR5000
RS-232 Interface – Get All
parameters
CM SE
G
Returns all serial communication param-
eter values in an XML element.
Example
: CMSEG
RS-232 Interface – Baud
Rate
CM SE
S/P/R/
G
BA
115200 1200
1200 Bits per second
Example:
CMSESBA1200
2400
2400 Bits per second
Example:
CMSESBA2400
4800
4800 Bits per second
Example:
CMSESBA4800
9600
9600 Bits per second
Example:
CMSESBA9600
1920
0
19200 Bits per second
Example:
CMSESBA19200
3840
0
38400 Bits per second
Example:
CMSESBA38400
5760
0
57600 Bits per second
Example:
CMSESBA57600
1152
00
115200 Bits per second
Example:
CMSESBA115200
Supported Baud Rate