Configuration and diagnostics software - Sensor Studio
Leuze electronic
DCR 55
16
6.2
Installing Sensor Studio configuration software
NOTICE
The installation files of the
Sensor Studio
configuration software must be downloaded from the
Internet at
www.leuze.com
.
For subsequent updates, you can find the most recent version of the
Sensor Studio
installation
software on the Internet at
www.leuze.com
.
6.2.1
Downloading configuration software
Ä
Call up the Leuze home page:
www.leuze.com
Ä
Enter the type designation or part number of the device as the search term.
Ä
The configuration software can be found on the product page for the device under the
Downloads
tab.
6.2.2
Installing the Sensor Studio FDT frame
NOTICE
First install the software!
Ä
Do not yet connect the device to the PC. First install the software.
NOTICE
If FDT frame software is already installed on your PC, you do not need the
Sensor Studio
instal-
lation.
You can install the communication DTM and the device DTM in the existing FDT frame. Com-
munication DTM and device DTM are included in the
LeAnalysisCollectionSetup
installation
package.
Ä
Start the PC.
Ä
Download the configuration software from the Internet to the PC (see chapter 6.2.1 "Downloading con-
figuration software").
Unpack the installation package.
Ä
Start the
SensorStudioSetup.exe
file.
Ä
Follow the instructions on the screen.
The Installation Wizard installs the software and places a shortcut on the desktop (
).
6.2.3
Installing the communication DTM and the device DTM
Prerequisites:
ü
An FDT frame is installed on the PC.
Ä
Start the LeAnalysisCollection.exe file from the installation package and follow the instructions on the
screen.
The installation wizard installs communication DTM and device DTM for DCR 55.
6.2.4
Connecting device to PC
The device is connected to the PC via the RS 232 interface or via the USB interface.
• You need an RS 232 connection or a USB connection that establishes the RxD, TxD and GND connec-
tions between PC and device (see chapter 5.4 "PC or terminal connection").
• The 5 V DC voltage supply is to be fed in externally (see chapter 5.1 "Voltage supply").
NOTICE
The MA-CR modular adapter unit with spring terminals and plug connector for connecting the
device, as well as a D-SUB 9-pin socket for connecting an RS 232 interconnection cable, is
available as an accessory (see chapter 13 "Order guide and accessories").
The MA-CR modular adapter unit requires 10 V … 30 V DC as external voltage supply, which
can be fed in via spring terminals.