Configuration and diagnostics software - Sensor Studio
Leuze electronic
DCR 55
19
•
Decode
(see chapter 6.5.2 "Decode tab")
•
Communications
(see chapter 6.5.3 "Communications tab")
•
Diagnosis
(see chapter 6.5.4 "Diagnosis / Terminal")
NOTICE
The online help system displays information on the menu items and configuration parameters
for each function. Select the
Help
menu item in the menu [?].
6.5.1
Control tab
Fig. 6.3:
Control tab
SCAN OPTIONS
Maximum labels to decode
The device processes up to this number of codes per
read code
event.
• If there are more codes in the field of view and within target toler-
ance and the device is set to decode more than one code, it will
decode all codes in the field of view.
• Set to 1 for fastest performance with single codes.
Targeting
Switch the blue targeting LED on and off.
DECODE OUTPUT OPTIONS
Output Result with AIM ID
Allows for the output of the AIM symbology identifier with the decode
result.
Barcode Prefix / Suffix enabled
Enables/ disables the output of prefix and suffix text with the decode
result.
Barcode Prefix text
Barcode Suffix text
Defines text of up to 255 characters that is added before/after the de-
code result.