Technical data
Leuze electronic
DCR 55
75
Tab. 12.5:
Mechanical data
Connection type
• 6-pin open-ended flying lead connector
• 4-pin USB 2.0 Standard A connector
• 8-pin M12 cable connector
Weight
89 g
Dimensions (H x W x D)
31.5 x 20 x 40.3 mm
Fastening
2x M2.5 threaded mounting holes, 5 mm deep
Tab. 12.6:
Environmental data
Ambient temp. (operation/storage)
0 °C … +50 °C/-20 °C … +60 °C
Air humidity
10 % … 90 % rel. humidity, non-condensing
Ambient light
max. 100000 Lux
Electromagnetic compatibility
EN 61326-1 Class B
Photobiological safety
IEC 62471:2006
Conformity
CE, FCC, UL, RoHS
12.2
Reading fields
NOTICE
Please note that the actual reading fields are also influenced by factors such as labeling mate-
rial, printing quality, scanning angle, printing contrast etc., and may thus deviate from the read-
ing fields specified here. The origin of the read distance always refers to the front edge of the
housing of the beam exit.