Leuze electronic
CMS 700i
– Contour Measurement System
Page 37
7
Right
On top
Left
Width, height:
Reverse counting direction
8
Right
On top
Right
Length, width, height:
Reverse counting direction
7.2.2 Setup with 2 light curtains and 1 rotary encoder
NOTICE
Enter conveying direction first!
Note that you must first enter the conveying direction of the measured objects.
Figure 30: Determination of coordinate origin for 2 light curtains and 1 rotary encoder
NOTICE
Evaluation of Figure 30!
Select your installation scenario from the table below!
The words light curtain are abbreviated as CML.
Depending on the existing installation situation, the counting direction of one or more light curtains
may have to be inverted. Please make the settings in WebConfig according to chapter 8.2.1.1.
Install. scenario
Conveying
direction
Width CML
Height CML
Settings WebConfig
1
Left
Left
On top
Height, Width
Reverse counting
direction
2
Left
Left
Below
Width
Reverse counting
direction
3
Left
Right
On top
Height
Reverse counting
direction
4
Left
Right
Below
-