Leuze electronic
CMS 700i
– Contour Measurement System
Page 52
Initial data
Address
Data type Range
Description
System OK
0.0
Bit
0..1
1: System is error free
Sensor OK
0.1
Bit
0..1
1: Sensors are error free
Length sensor NOK
0.2
Bit
0..1
1: Error at length sensor
Width sensor NOK
0.3
Bit
0..1
1: Error at width sensor
Height sensor NOK
0.4
Bit
0..1
1: Error at height sensor
System ready
0.5
Bit
0..1
1: System ready for next
measurement
Reserved
0.6
Bit
0..1
Reserved
Toggle bit
0.7
Bit
0..1
Toggle bit is toggled every
500 ms
Error code
1
Byte
0..255
See chapter 9.3!
New result
2.0
Bit
0->1: New
result
1->0: New
result
Toggle bit indicates whether a
new result is applied
Overflow
2.1
Bit
0..1
Indicates that the output data
string was longer than 196 bytes
and that some data were
discarded.
Reserved
2.2..2.7
6x Bit
0..1
Reserved
Result data length
3
Byte
0..196
Length of the subsequent result
data string
Result data
4..199
196x Byte
0..255
Result data string (ASCII coded)
Input data length: 200 Byte