Leuze electronic
CMS 700i
– Contour Measurement System
Page 39
Operational
settings
IO-Link
Bit rate
COM3: 230,4
COM2: 38,4
PD Length
2 Bytes
8 Bytes
32 Bytes
Data storage
Deactivated
Activated
7.3.2 Setting up the length light curtain
The necessary configuration for the height and width light curtain is as follows:
Process data length (PD Length): 8 Bytes
Bit rate: COM3: 230,4
Data storage: Deactivated
The configuration in the Receiver Panel menu is as follows:
Level 0
Level 1
Level 2
Description
Main settings
Commands
Operational
settings
IO-Link
Bit rate
COM3: 230,4
COM2: 38,4
PD Length
2 Bytes
8 Bytes
32 Bytes
Data storage
Deactivated
Activated
7.3.3 Setting up the rotary encoder
Make sure that the encoder is correctly installed and aligned, see the package insert of the encoder.
The encoder does not require any special settings.
7.4 Determining the correct height and width offset
The offset refers to the mounting position of the light curtain. Depending on the distance to the
conveyor belt, the offset can be different in each system.
7.4.1 Height offset
In principle, the 1st beam of the HEIGHT light curtain should be in alignment with the conveying
medium, see Figure 31.
NOTICE
If the HEIGHT light curtain is mounted above the conveyor
The mechanical offset between the conveyor level and the 1st beam of the HEIGHT light
curtain must be measured in millimeters, see Figure 32.
Note the value here.
Enter the offset value in WebConfig, see chapter 8.2.1.2!