8 System configuration via WebConfig
8.1 Setting IP address
Connect the PC and LSC box via the XETH1 connector see
. One of the following accessory
cables can be used for this purpose, see chapter 13.5.
Set your network adapter to an IP address in the 192.168.60.XXX range. For example, you could use
192.168.60.100 for the computer.
The default
IP address of the LSC box is 192.168.60.101
.
In your web browser, type in the IP address of the LSC box. You will be taken directly to the
WebConfig start page.
WebConfig is explained by the help texts displayed on the right.
8.2 Parameter setting
8.2.1 Light curtain setting
The following procedure is mandatory for each light curtain.
8.2.1.1 Setting for the System Coordinate Origin
NOTICE
Observe your mounting situation!
First determine your mounting situation according to the chapter
Fehler! Verweisquelle
konnte nicht gefunden werden.
! The mounting situation specifies the setting of the light curtains.
Set the checkbox for
Reverse counting direction
for the length, width and height light curtain, if your
determined scenario requires it.
Figure 34: Checkbox Reverse counting direction of the light curtain