Appendix
Code list
145
EDBCSXE040 EN 6.0
Parameter
C0354
Designation
CAN_IN/OUT ID offset
Data type: INTEGER_32
Index: 24221
dec
= 5E9D
hex
ID offset for calculating individual COB−IDs: COB−ID = 384 + ID offset
Note:
l
This code is not active if one of the switches 2 ... 7 of the DIP switch is set to "ON".
l
After the setting, a reset node is required.
Setting range
(min. value | unit | max. value)
0
513
Subcodes
Lenze setting
Information
C0354/1
32
ID offset for COB−ID CAN1_IN
C0354/2
160
ID offset for COB−ID CAN1_OUT
C0354/3
288
ID offset for COB−ID CAN2_IN
C0354/4
289
ID offset for COB−ID CAN2_OUT
C0354/5
416
ID offset for COB−ID CAN3_IN
C0354/6
417
ID offset for COB−ID CAN3_OUT
Parameter
C0355
Designation
CAN_IN/OUT identifier (COB−IDs)
Data type: INTEGER_32
Index: 24220
dec
= 5E9C
hex
Display of the CAN_IN/OUT identifiers (COB−IDs)
Display range
(min. value | unit | max. value)
0
2047
Subcodes
Information
C0355/1
COB−ID CAN1_IN
C0355/2
COB−ID CAN1_OUT
C0355/3
COB−ID CAN2_IN
C0355/4
COB−ID CAN2_OUT
C0355/5
COB−ID CAN3_IN
C0355/6
COB−ID CAN3_OUT